Posted by Stephen on November 28, 2000 at 07:42:44:
In Reply to: Adjusting Top Mounted Rangefinder posted by Kevin Crisp on November 27, 2000 at 19:03:21:: I need help. I have a Pacemaker with the top mounted
: plastic rangefinder. I got it right at infinity by
: moving the infinity stops to where they should be. I
: fixed the lateral coincidence where it was off. It
: works great until I get closer than about 12', at that
: point the negative is only in focus if I deliberately
: put the movable image about a thumb's width off to the
: right in the rangefinder. I could fix this easily on
: the Kalart and have done so on my other camera using
: the instructions on this site. But I can't find an
: instruction about this problem on this rangefinder.
: Any suggestions? Thanks.
You have to change a cam in the rangefinder.
Information about this, is on this web site.
Stephen